Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Braz. j. oral sci ; 22: e237699, Jan.-Dec. 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1437668

ABSTRACT

Aim: Dental number anomalies are a group of congenital developmental disorders divided into two groups supernumerary and missing teeth. This study was conducted to investigate the prevalence of numeric dental anomalies using panoramic images in patients referred to the Hamadan Dental Faculty. Methods: In this cross-sectional study, 2,197 panoramic radiographs of patients aged 6-49 years were evaluated. These anomalies are divided into two groups: 1) Supernumerary teeth, including Mesiodens, Distodens, and Peridens, and 2) Missing teeth, including Hypodontia, Oligodontia, and Anodontia. A Chi-square test was performed to assess the relationship between the anomalies. Data analysis was performed using SPSS 16, in which P-value < 0.05 was considered the statistical significance level. Results: Of 736 males (32.2%) and 1548 females (67.8%) in this study, 32 (4.3%) and 55 cases (3.8%) had supernumerary teeth, respectively. The prevalence of supernumerary teeth was 0.3%, 0.5%, and 0.6% in males and 0.2%, 1% and 1.2% in females for mesiodens, distodens, and peridens, respectively. Also, 243 males (10.6%) and 655 females (28.6%) had missing teeth anomalies. Hypodontia in the maxilla was the most common anomaly in both genders, while mesiodens was the least common. Conclusion: Hypodontia was the most common anomaly, followed by peridens; the least common anomaly was mesiodens. The prevalence of supernumerary teeth was greater in males, though the difference was not statistically significant. In comparison, females had a greater prevalence of missing teeth


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Tooth Abnormalities/epidemiology , Radiography, Panoramic , Anodontia
2.
Braz. dent. sci ; 24(1): 1-9, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1145533

ABSTRACT

Objective: Sex determination is one of the most important parameters to identify in forensic science. Because the mastoid process is the most resistant to damage due to its position in the skull base, it can be used for sex determination. The purpose of this study was to measure the dimensions and convexity and internal angles of the mastoid process to present a model of sex determination in Iranian population. Material and methods: This study was performed on three-dimensional images of 190 Cone Beam Computed Tomography (CBCT) of 105 women and 85 men. On each CBCT the distance between the porion and the mastoid (PM), mastoid length (ML), the distance between the mastoidale and the mastoid incision (M-I), the mastoid height (MH), the mastoid width (MW), intermastoidale distance (IMD) the lateral surfaces of the left and right mastoids (IMLSD) and the Mastoid medial convergence angle (MMCA) was measured on both the right and the left. The data were analyzed by descriptive statistics, t-test, and discriminant function analysis. Results: Significant differences were found for all variables except MMCA and MF in both sex. All measured variables except MW were greater for men than women. The discriminant model achieved a total accuracy of 93.7%. Among the measured factors IMD and IMSLD had the most influence on sex determination. Conclusion: Measuring the dimensions of the mastoid process is a very good method for sex determination with high accuracy of 90% (AU)


Objetivo: A determinação do sexo é um dos parâmetros mais importantes para identificação na ciência forense. Por ser o processo mastóide resistente a danos, devido a sua posição na base do crânio, este poderia ser usado na determinação do sexo. O objetivo deste estudo foi mensurar as dimensões, convexidade e ângulos internos do processo mastóide para apresentar um modelo de determinação do sexo em uma população Iraniana. Material e métodos: Este estudo foi realizado em 190 imagens de tomografia computadorizada de feixe cônico (TCFC), sendo 105 mulheres e 85 homens. Em cada TCFC foram realizadas medidas no processo mastóide em comprimento (ML), altura (MH), largura (MW) em ambos os lados direito e esquerdo, também foi medida a distância entre o Pórion e o processo mastóide (PM), distância até incisura mastoidea (M-I), distância entre as superfícies mediais (IMD) distância entre as superfícies laterais dos processos direito e esquerdo (IMLSD) e o ângulo de convergência medial (MMCA). Os dados foram analisados por estatística descritiva, teste t e análise de função discriminante. Resultados: Diferenças significativas foram encontradas para todas as variáveis, exceto MMCA e MF em ambos os sexos. Todas as variáveis medidas, exceto MW, foram maiores para os homens do que para as mulheres. O modelo de análise de função discriminante alcançou uma precisão total de 93,7%. Entre os fatores medidos, o IMD e o IMSLD tiveram a maior influência na determinação do sexo. Conclusão: Podemos concluir que as dimensões do processo mastóide constituem um método para determinação do sexo, em população Iraniana, com precisão de 90% (AU)


Subject(s)
Humans , Male , Female , Sex Determination Analysis , Cone-Beam Computed Tomography , Mastoid
3.
Braz. dent. sci ; 24(2): 1-12, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1178269

ABSTRACT

Objetive: This study aimed to compare the anatomical characteristics of the mandible in patients with skeletal class I, II and class III disorders using cone beam computed tomography (CBCT). Material and Methods: CBCT scans of patients between 17 to 40 years taken with NewTom 3G CBCT system with 12-inch field of view (FOV) were selected from the archive. Lateral cephalograms were obtained from CBCT scans of patients, and type of skeletal malocclusion was determined (Class I, II or III). All CBCT scans were evaluated in the sagittal, coronal and axial planes using the N.N.T viewer software. Results: The ramus height and distance from the mandibular foramen to the sigmoid notch in class II patients were significantly different from those in skeletal class I (P < 0.005). Distance from the mandibular canal to the anterior border of ramus in class III individuals was significantly different from that in skeletal class I individuals (P < .005). Conclusion: Length of the body of mandible in skeletal class I was significantly different from that in skeletal class II and III patients. Also, ramus height in skeletal class I was significantly different from that in skeletal class II patients. CBCT had high efficacy for accurate identification of anatomical landmarks. (AU)


Objetivo: Este estudo teve como objetivo comparar as características anatômicas da mandíbula em pacientes com desordem esquelética Classe I, II e III usando imagens de tomografia computadorizada de feixe cônico (TCFC). Material e Métodos: Foram selecionadas de arquivo, imagens de TCFC (Sistema NewTon 3G) com FOV (campo de visão) 12 polegadas e incluindo pacientes entre 17 a 40 anos. Cefalometrias laterais foram obtidas a partir das imagens de TCFC e o tipo de maloclusão esquelética foi determinada (Classe I, II ou III). Todas as imagens de TCFC foram avaliadas nos planos sagital, coronal e axial usando o software de visualização N.N.T. Resultados: A altura do ramo e distância do forame mandibular para a incisura da mandíbula em pacientes Classe II foi significativamente diferente daqueles Classe I esquelética (p< 0.005). A distância do canal mandibular até a borda anterior do ramo em indivíduos Classe III foi significativamente diferente daqueles indivíduos Classe I esquelética (p<0.005). Conclusão: O comprimento do corpo da mandíbula na Classe I esquelética foi diferente significativamente daqueles pacientes em Classe II e III esquelética. Além disso, a altura do ramo na Classe I esquelética foi significativamente diferente daqueles pacientes Classe II esquelética. A TCFC apresentou alta eficácia para a identificação precisa de marcos anatômicos. (AU)


Subject(s)
Humans , Adolescent , Adult , Prognathism , Retrognathia , Cone-Beam Computed Tomography , Anatomy , Mandible
4.
Braz. dent. sci ; 24(2): 1-10, 2021. tab
Article in English | LILACS, BBO | ID: biblio-1177598

ABSTRACT

Objective: TThis study aimed to assess the knowledge level of Iranian dental practitioners about digital radiography (DR) and cone-beam computed tomography (CBCT). Material and Methods: In this cross-sectional study, a researcher-designed questionnaire was administered among 180 general dentists and specialists. The questionnaire had three main domains of demographic information, fifteen questions about knowledge of DR (advantages, disadvantages, physical properties) and twenty six questions about knowledge of CBCT (indications, applications, advantages, route of knowledge acquisition). Data were analyzed using descriptive statistics, t-test and Pearson's correlation coefficient. Results: Of 180 participants, 76 (42.2%) were females. The minimum, maximum and mean± standard deviation scores obtained in DR were 4, 14, and 9.031 ± 1.85 and in CBCT were 0,26 and 18.56 ± 4.81, respectively. In the CBCT domain, the participants had maximum knowledge about "low radiation dose" (72.8%) and minimum knowledge about the "role of CBCT in determination of bone density" (45%). In DR domain, the participants had maximum knowledge about "no need for radiographic films" (75.6%) and minimum knowledge about "not requiring manual processing" (15.6%). Overall, participants had higher level of knowledge about CBCT than DR. An inverse correlation was noted between age and work experience with the number of correct answers. However, no significant difference was noted in the knowledge level of males and females regarding CBCT or DR (p = 0.233 and p = 0.227, respectively). Conclusions: further education seem imperative for dentists in this respect for more efficient diagnosis and treatment planning, minimize patient radiation dose and save time and cost. (AU)


Objetivos: Avaliar o nível de conhecimento de dentistas iranianos sobre radiografia digital (RD) e tomografia computadorizada de feixe cônico (TCFC). Materiais e métodos: Neste estudo transversal, um questionário, elaborado por pesquisadores, foi aplicado a 180 dentistas clínicos geral e especialistas. O questionário tinha três domínios principais de informação demográfica, quinze questões sobre conhecimento de RD (vantagens, desvantagens, propriedades físicas) e vinte e seis questões sobre conhecimento de CBCT (indicações, aplicações, vantagens, protocolo de aquisição). Os dados foram analisados por meio de estatística descritiva, teste t e coeficiente de correlação de Pearson. Resultados: Dos 180 participantes, 76 (42,2%) eram do sexo feminino. Os escores mínimo, máximo e média ± desvio padrão obtidos na RD foram 4, 14 e 9,031 ± 1,85 e na CBCT foram 0, 26 e 18,56 ± 4,81, respectivamente. No domínio CBCT, os participantes tinham conhecimento máximo sobre "baixa dose de radiação" (72,8%) e conhecimento mínimo sobre o "papel da CBCT na determinação da densidade óssea" (45%). No domínio RD, os participantes possuíam conhecimento máximo sobre "não há necessidade de filmes radiográficos" (75,6%) e conhecimento mínimo sobre "não requer processamento manual" (15,6%). No geral, os participantes tinham maior nível de conhecimento sobre CBCT do que RD. Foi observado correlação inversa entre idade e experiência de trabalho com o número de acertos. No entanto, nenhuma diferença significativa foi observada no nível de conhecimento de homens e mulheres sobre TCFC ou RD (p = 0,233 e p = 0,227 respectivamente). Conclusão: Parece imperativo para os dentistas iranianos, mais educação nesse aspecto para diagnóstico e planejamento de tratamento mais eficientes, minimizar a dose de radiação para paciente, economizar tempo e custos. (AU)


Subject(s)
Humans , Radiographic Image Enhancement , Dentists , Cone-Beam Computed Tomography
5.
Braz. dent. sci ; 23(4): 1-6, 2020. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1122349

ABSTRACT

Osteosarcoma is a relatively rare lesion in the maxillary bone. The proximity of the lesion to the maxillary sinus provides a null space with the minimum resistance to progress prior to manifest clinically, which makes the early diagnosis more critical. We report a case of maxillary osteosarcoma in a 21-year old male patient who was presented with the chief complaint of the pain and swelling on the left side of palate since 2 months earlier. A cone-beam computed tomography of the maxilla revealed a diffuse hyper-intense entity at the left side of the maxilla. Totally-occupied maxillary sinus space, asymmetric periodontal ligament widening of the involved teeth and spiculated and sunray periosteal reaction were recognized. The diagnosis of osteosarcoma was established and confirmed by histopathology. This article reviews the sinus-occupying lesion in the following and describes the lesions originate within the maxillary sinus or arise from the adjacent odontogenic components. (AU)


O osteossarcoma é uma lesão relativamente rara no osso maxilar. A proximidade da lesão ao seio maxilar proporciona um espaço vazio com resistência mínima ao progresso da lesão antes de se manifestar clinicamente, o que torna o diagnóstico precoce mais crítico. Relatamos um caso de osteossarcoma maxilar em um paciente do sexo masculino de 21 anos que se apresentou com queixa principal de dor e inchaço do lado esquerdo do palato desde 2 meses antes. Uma tomografia computadorizada Cone Beam da maxila revelou uma entidade hiperintensa difusa do lado esquerdo da maxila. Seio maxilar totalmente ocupado, alargamento assimétrico do ligamento periodontal dos dentes envolvidos e reação periosteal espiculada e em raios de sol foi reconhecida. O diagnóstico de osteossarcoma foi estabelecido e confirmado por histopatologia. Este artigo analisa a lesão que ocupa o seio maxilar e descreve as lesões originadas dentro do seio maxilar ou que surgem de componentes odontogênicos adjacentes (AU)


Subject(s)
Humans , Male , Adult , Case Reports , Osteosarcoma , Maxillary Sinus
6.
Braz. dent. j ; 29(3): 239-244, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-951551

ABSTRACT

Abstract Most failures in endodontic treatment of mandibular incisors are due to the presence of a missed canal specifically the lingual. This investigation aimed to examine the root morphology and number of canals in mandibular incisors using cone beam computed tomography (CBCT). Two hundred and seven patients were assessed in terms of their mandibular central and lateral incisors of CBCT. The inclusion criteria were absence of root resorption, coronal restoration or root filling and clarity and optimal resolution of images. According to the Vertucci's classification, number of roots and canals and type of canal were evaluated by two oral and maxillofacial radiologists. In order to data analysis SPSS version 16 and descriptive statistics were implemented. All mandibular incisors had one root. Most central (84.5%) and lateral (78.2%) incisors had a single canal (p= 0.065). The majority of central (54.5%) and lateral (56.5%) incisors were Vertucci's type I (p= 0.102). Prevalence of one canal in males: central (84.8%), lateral (77.9%) and in females: central (84.2%), lateral (78.5%) (p= 0.518). Prevalence of Vertucci's type I in males: central (52.3%), lateral (45.3%) and in females: central (56.1%), lateral (64.4%) (p=0.188). The prevalence of two canals was 15.5% (central) and 21.8% (lateral) in mandibular incisors. The Vertucci's type I was the most typical kinds of mandibular incisors. Considering the limitations of periapical radiography in determining canal morphology, CBCT can be helpful in case of any concern regarding root canal morphology.


Resumo A maioria das falhas no tratamento endodôntico dos incisivos mandibulares é devida à presença de um canal perdido, especificamente do lingual. Esta investigação teve como objetivo analisar a morfologia radicular e o número de canais nos incisivos inferiores utilizando a tomografia computadorizada de feixe cônico (TCFC). Duzentos e sete pacientes foram avaliados em termos de seus incisivos centrais e laterais mandibulares de TCFC. Os critérios de inclusão foram ausência de reabsorção radicular, restauração coronária ou preenchimento radicular e clareza e resolução ótima das imagens. De acordo com a classificação de Vertucci, o número de raízes e canais e o tipo de canal foram avaliados por dois radiologistas orais e maxilo-faciais. Para análise dos dados, o SPSS versão 16 e análise estatística descritiva foram implementados. Todos os incisivos inferiores tinham uma raiz. A maioria dos incisivos centrais (84,5%) e laterais (78,2%) apresentava um único canal (valor de P: 0,065). A maioria dos incisivos centrais (54,5%) e laterais (56,5%) eram do tipo I de Vertucci (valor de P: 0,102). Prevalência de um canal no sexo masculino: central (84,8%), lateral (77,9%) e no feminino: central (84,2%), lateral (78,5%) (valor de P: 0,518). Prevalência de Vertucci tipo I em homens: central (52,3%), lateral (45,3%) e feminina: central (56,1%), lateral (64,4%) (valor de P: 0,188). A prevalência de dois canais foi de 15,5% (central) e 21,8% (lateral) nos incisivos inferiores. O tipo I de Vertucci era dos tipos mais comuns de incisivos inferiores. Considerando as limitações da radiografia periapical na determinação da morfologia do canal, a TCFC pode ser útil em caso de qualquer preocupação com relação à morfologia do canal radicular.


Subject(s)
Humans , Male , Female , Tooth Root/diagnostic imaging , Dental Pulp Cavity/diagnostic imaging , Cone-Beam Computed Tomography/methods , Incisor/diagnostic imaging , Mandible/diagnostic imaging , Tooth Root/anatomy & histology , Case-Control Studies , Dental Pulp Cavity/anatomy & histology , Incisor/anatomy & histology , Mandible/anatomy & histology
7.
Braz. dent. j ; 28(1): 85-91, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839115

ABSTRACT

Abstract Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations. mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (p<0.05). The accuracy was 0.83, 0.78, 0.55 and 0.49 for CBCT Cranex 3D, CBCT NewTom 3G, conventional and digital intraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations.


Resumo A causa mais comum de falha das cáries dentais são as cáries secundárias. Este estudo objetivou comparar a acurácia diagnóstica da radiografia intraoral digital e convencional com a tomografia computadorizada de feixe cônico (TCFC) para a detecção de cáries recorrentes em torno restaurações com compósitos. Cavidades mésio-oclusais-distais (MOD) foram produzidas com broca em 45 molares hígidos humanos extraídos. Os dentes foram dividdos em 3 grupos. No grupo controle, as cavidades foram restauradas com compósito após condicionamento e colagem (n=15). No Grupo 2, foi aplicada uma camada de cera de 500 µm de espessura sobre as paredes bucais, linguais e gengivais; as cavidades foram então restauradas com resina composta. No Grupos 3, as amostras foram submetidas a ciclagem de pH e criação artificial de cáries sobre as paredes bucais, linguais e gengivais; as cavidades foram então restauradas com resina composta. Radiografias convencional e digital com fósforo foto-estimulável (PSP, Optima) e duas imagens em TCFC (NewTom 3G e Granex 3D) foram obtidas de cada amostra. A presença ou não de cáries foi avaliada nestas imagens. Os dados foram analisados por estatística Kappa. A acurácia diagnóstica da TCFC foi significantemente (p<0,05) maior que na radiografia intraoral convencional e digital. A acurácia foi de 0,83, 0,78, 0,55 e 0,49, respectivamente para TCFC Cranex 3D, TCFC NewTom 3G, a radiografia intraoral convencional e digital. A TCFC tem maior acurácia diagnóstica que a radiografia intraoral convencional e digital para detecção de cáries secundárias em torno de restaurações com compósito.


Subject(s)
Humans , Composite Resins , Cone-Beam Computed Tomography/methods , Dental Caries/diagnosis , Dental Restoration, Permanent , Dental Caries/therapy , Radiography, Dental, Digital/methods , Recurrence , Sensitivity and Specificity
8.
Braz. dent. j ; 27(5): 604-608, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-828040

ABSTRACT

Article Incorrect patient positioning and the resultant image distortion occur in many radiographic examinations. This study aimed to assess the effect of tilting, rotation and tipping of the head on the accuracy of maxillofacial transverse measurements made on cone beam computed tomography (CBCT) scans. The CBCT scans were obtained in central position of 10 dry human skulls. Using three-dimensional (3D) Dolphin software, six positions namely 10° and 20° tilts, rotations and tips were reconstructed of central position. Transverse distances between landmarks were measured on 3D scans and the skulls. The intraclass correlation coefficient (ICC) and the Bland-Altman plot were used to compare the mean values measured by the two observers. For most landmarks, no significant differences were noted between the mean transverse distances measured in the six positions and those measured in central position on 3D scans (p>0.005). In conclusion, all measurements of transverse distances made on 3D scans in different positions were underestimated compared to the actual values measured on the skull.


Subject(s)
Humans , Cone-Beam Computed Tomography/methods , Face/diagnostic imaging , Maxilla/diagnostic imaging , Patient Positioning
9.
Braz. dent. j ; 27(1): 16-21, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-777154

ABSTRACT

Abstract Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog's teeth. Forty-eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans.


Resumo Um diagnostico correto e a tempo das fraturas radiculares verticais (FRVs) é essencial para prevenir extensa perda óssea, tratamentos endodônticos e próteses desnecessárias. O objetivo do presente estudo foi avaliar o efeito do tempo decorrido sobre a acurácia diagnóstica da tomografia computadorizada de feixe cônico (TCFC) para detecção de FRVs em dentes de cães tratados endodonticamente. Quarenta e oito dentes incisivos e premolares obtidos de três cães machos adultos tiveram os seus canais tratados. Os dentes foram divididos em dois grupos: no primeiro grupo (n=24) foram artificialmente induzidas FRVs, enquanto no segundo grupo (n=24) os dentes permaneceram intactos. As imagens de TCFC foram obtidas pela unidade NewTom 3G imediatamente após a cirurgia de indução das FRVs e uma, duas, três, quarto, oito, 12 e 16 semanas depois. Três radiologistas cegos para as datas das imagens avaliaram a presença/ausência de FRVs nas imagens de TCFC. Foram calculados os valores da sensibilidade, especificidade e acurácia, sendo os dados analisados por ANOVA e pelo programa SPSS v.16. As acurácias totais de detecção das FRVs imediatamente após sua indução e uma, duas, três, quarto, oito, 12 e 16 semanas depois foram respectivamente de 67,3%, 68,7%, 66,6%, 64,6%, 64,5%, 69,4%, 68,7% e 68%. O efeito do tempo decorrido foi sem significado estatístico (p>0,05). A TCFC produziu valores gerais de sensibilidade, especificidade e acurácia de 74,3%, 62,2% e 67.2%, respectivamente. A tomografia computadorizada de feixe cônico é uma ferramenta valiosa para detecção de FRVs. O tempo decorrido (quatro meses) não teve influência sobre a detecção de FRVs nas imagens de TCFC.


Subject(s)
Animals , Male , Cone-Beam Computed Tomography/standards , Tooth Fractures/diagnostic imaging , Tooth Root/injuries , Dogs , Sensitivity and Specificity , Time and Motion Studies
10.
Braz. dent. sci ; 17(3): 74-82, 2014. ilus, tab
Article in English | LILACS, BBO | ID: lil-743032

ABSTRACT

Objective: The aim was to investigate the accuracy of linear measurements of the mandibular ridge recorded using two CBCT systems. Material and Methods: Eleven human dry skull were used in which mandibles were chosen to measure width and height in 6 sites. Before scanning, the points were marked using barium sulfate radiopaque contrast media. Mandible imaging was done using two systems: Newtom3G and Cranex3D. Alveolar ridge dimensions were recorded by two observers under uniform condition using special software for each system. The measurement errors and inter-examiner reliability were calculated for each modality and compared with each other and analyzed via SPSS software version 18. The level of significance was set at P < 0.05. Results: The overall mean was 0.08 mm for Cranex system and 0.5 for Newtom system. The mean of two systems had no statistically significant difference in comparison with each other or with the gold standard. The statistical analysis showed high inter-observer reliability (P < 0.05). Conclusion: CBCT is highly accurate and reproducible in linear measurements in the different areas of the maxillofacial region.


Objetivo: O objetivo deste estudo foi investigar a acurácia de medidas lineares do rebordo mandibular utilizando dois sistemas de TCFC. Material e Métodos: Onze crânios secos humanos foram utilizadas e seis regiões das mandíbulas foram escolhidos para mensuração da largura e da altura. Antes da digitalização, os pontos foram marcados com contraste radiopaco de sulfato de bário. Imagens da mandíbula foram realizadas usando dois sistemas: Newtom3G e Cranex3D . As dimensões rebordo alveolar foram determinadas por dois observadores em condições uniformes utilizando software específico para cada sistema. Os erros de medição e confiabilidade interexaminadores foram calculados para cada modalidade, utilizando o software SPSS versão 18, e comparados entre si. O nível de significância adotado foi p < 0,05. Resultados: A média geral para o sistema Cranexfoi de 0,08 mm e 0,5 para o sistema de Newton. As médias dos dois sistemas não apresentaram diferença estatisticamente significativa em comparação entre si ou com o padrão-ouro. A análise estatística mostrou alta confiabilidade interexaminador (p < 0,05). Conclusão: TCFC é altamente precisa e reprodutível em medidas lineares nas diferentes áreas da região maxilofacial.


Subject(s)
Humans , Barium Sulfate , Cone-Beam Computed Tomography , Dental Implantation
11.
Braz. dent. sci ; 17(4): 74-81, 2014. tab
Article in English | LILACS | ID: lil-742514

ABSTRACT

Objective: Mandibular foramen (MF) is located on the internal surface of the ramus through which blood vessels and nerves pass. Determination of the anatomic position of the MF is very important in inferior alveolar nerve block anesthesia (IANBA), ramus osteotomy and surgical procedures of the posterior angle of mandibular ramus. The aim of this study was to determine anatomic position of the MF using anatomic landmarks on the three dimensional CBCT images. Material and Methods: A total of 103 CBCT images was evaluated. The NNT Viewer software program was used to measure the distances between the lines tangent on the MF periphery and the anterior border of the ramus, the posterior border of the ramus, the inferior border of the mandible, and the coronoid notch in mm by to age and gender. Results: The results showed a slight difference in anatomic dimensions between the right and left sides, with no significant differences. The anatomic dimensions of the MF on both sides were a little bigger in males than in females. There were no significant differences in the anatomic dimensions of superior inferior and anterior-posterior dimensions of the left and right sides in different age groups. Conclusion: No significant changes occur in the position of the MF with age. The anatomic differences between males and females should be taken into account during IANBA procedures. Males have bigger jaws than females; therefore, there is a longer distance between the MF and the anatomic landmarks evaluated...


Objetivo: O forame mandibular (FM) localiza-se na superfície interna do ramo mandíbula, onde passam vasos sanguíneos e nervos. A determinação da posição anatômica do FM é muito importante para anestesia por bloqueio do nervo alveolar inferior (ABNAI), durante osteotomiano ramo da mandíbula e para procedimentos cirúrgicos do ângulo posterior do ramo mandibular. O objetivo deste estudo foi determinar a posição anatômica do FM utilizando referências anatômicas em imagens tridimensionais de CBCT. Material e Métodos: Um total de 103 imagens de CBCTforam avaliadas. O programa de software NNT Viewer foi utilizado para medir as distâncias em milímetros entre as linhas tangentes na periferia do FM e borda anterior do ramo, borda posterior do ramo, borda inferior da mandíbula e processo coronóide, em relação à idade e o gênero. Resultados: Os resultados mostraram uma ligeira diferença de dimensões anatômicas entre os lados direito e esquerdo, sem diferenças significativas. As dimensões anatômicas do FM em ambos os lados foram um pouco maior no sexo masculino do que no feminino. Não houve diferenças significativas nas dimensões anatômicas superior-inferior e ânteroposterior, tanto do lado direito quanto esquerdo,em diferentes faixas etárias. Conclusão: Mudanças significativas na posição do FM não são observadas em função da faixa etária. As diferenças anatômicas entre homens e mulheres devem ser levadas em consideração durante procedimento ABNAI. Mandíbulas maiores são encontradas no gênero masculino, portanto, há uma maior distância entre o FM e as referências anatômicas avaliadas...


Subject(s)
Humans , Male , Female , Anatomic Landmarks , Cone-Beam Computed Tomography , Mandible
12.
Braz. dent. sci ; 17(1): 72-80, 2014. ilus, tab
Article in English | LILACS, BBO | ID: lil-728103

ABSTRACT

Objective: Various radiographic methods are used to identify the internal root resorption. The aim of this study was to assess and compare the diagnostic accuracy of cone-beam computed tomography (CBCT), photostimulable phosphor (PSP) imaging plate, charge coupled device (CCD), and conventional intraoral radiography (CIR), for internal root resorption. Material & Methods: This experimental study was conducted in Hamadan in 2012. Fifty seven carries-free single-rooted teeth were divided into three intervention groups of 15 teeth and one control group of 12 teeth. Teeth were split into two parts using a disk. Cavities of 0.5, 1 and 1.5 mm in depth were created in root canal of teeth to simulate internal root resorption artificially. Finally, the teeth fragments were fused. All teeth were examined with four different procedures and the results were compared with known simulated internal root resorption as the gold standard to determine the sensitivity and specificity of the procedures. Results: The sensitivity of CBCT, PSP, CCD, and CIR for diagnosis internal root resorption of 0.5 mm in depth was 93%, 73%, 60%, and 53% respectively. The sensitivity of all four procedures for diagnosis of internal root resorption with 1 and 1.5 mm in depth was the same and equal to 100%. Specificity of the four radiology procedures for diagnosis of internal root resorption of any depth was 100%, 100%, 83% and 75% respectively. Conclusion: CBCT provides the most accurate information on the depth and location of root resorption followed by the PSP and CCD respectively. Accordingly, conventional intraoral radiography was the least accurate procedure


Objetivos: Vários métodos radiográficos são utilizados para identificar a reabsorção radicular interna. O objetivo deste estudo foi avaliar e comparar a precisão do diagnóstico de reabsorção radicular interna por tomografia computadorizada de feixe cônico (TCFC), placa de imagem de fósforo fotoestimulável(FFE), Charge CoupledDevice( CCD) e radiografia intra-oral convencional (RIC). Material e Métodos: Este estudo experimental foi realizado em Hamadan em 2012. Cinqüenta e sete dentes anteriores livres de cárie foram divididos em três grupos de 15 dentes e um grupo de 12 dentes foi utilizado como controle. Os dentes foram divididos em duas partes usando um disco. Cavidades de 0,5, 1 e 1,5 mm de profundidade foram criados nos canais radiculares dos dentes para simular a reabsorção radicular interna artificialmente. A seguir , os fragmentos de dentes foram unidos . Todos os dentes foram examinados com quatro diferentes procedimentos e os resultados foram comparados com um padrão ouro conhecido de diagnóstico de reabsorção radicular interna simulada para determinar a sensibilidade e especificidade dos procedimentos. Resultados: A sensibilidade da TCFC, FFE, CCD e RIC para diagnóstico reabsorção radicular interna de 0,5 mm de espessura foi de 93 %, 73 %, 60 % e 53 %, respectivamente. A sensibilidade dos quatro processos para o diagnóstico da reabsorção radicular interna com 1 e 1,5 mm de profundidade foi a mesma e igual a 100 %. A especificidade dos quatro procedimentos de radiologia de diagnóstico de reabsorção radicular interna de qualquer profundidade foi de 100 %, 100 %, 83 % e 75 %, respectivamente. Conclusão: A TCFC fornece as informações mais precisas sobre a profundidade e localização da reabsorção radicular, seguido pelo FFE e CCD, respectivamente. Assim, a radiografia intra-oral convencional foi o procedimento menos preciso.


Subject(s)
Humans , Cone-Beam Computed Tomography , Radiography , Root Resorption
SELECTION OF CITATIONS
SEARCH DETAIL